CW-APHydrophobic Silica Aerogel Powder and Particles
Nanoporous SiO2 aerogel raw material for coatings, composite fillers and functional modification systems.
- 400-800 m2/g specific surface area
- 90-95% porosity
- 20-50 nm pore size
- Hydrophobic surface
Waterborne industrial coatingsThermal coating formulasComposite fillers
Designed against JC/T 2518-2019 requirements for hydrophobic silica aerogel powder.
View technical profileCW-AT-H / CW-AT-LAerogel Blanket for Industrial Insulation
Flexible aerogel blankets for medium-high temperature insulation, cryogenic service, tanks, pipelines and constrained spaces.
- 0.020 W/(m·K) at 25C
- Up to 650C service for CW-AT-H
- -200C to 125C for CW-AT-L
- Hydrophobicity up to 99.9%
Steam pipelinesProcess equipmentLNG logisticsCold chain
Product quality aligned with GB/T 34336-2017 nanoporous aerogel composite insulation products.
View technical profileCW-AC-01/02Building Aerogel Thermal Insulation Coating
Waterborne thin-layer aerogel insulation coating used with primer and topcoat for exterior walls, roofs, retrofits and industrial buildings.
- 0.040 W/(m·K) tested thermal conductivity
- 0.26 m2·K/W added thermal resistance
- 35 g/L VOC
- 0.5 g/mL density
Exterior wallsRoof retrofitFactory buildingsEnergy-saving renovation
Shanghai Jianke XT226-250016 report: compliant with GB/T 25261-2018 and DG/TJ08-2200-2024.
View technical profileCW-AC-14/15/16Industrial Aerogel Insulation Coating
Sprayable or trowel-applied aerogel insulation coating for equipment, valves, elbows and complex industrial surfaces up to 180C.
- -40C to 180C service range
- ≤0.04 W/(m·K) thermal conductivity
- ≤1.5 mm single wet film
- Three-layer protection system
Hot equipmentPipe elbowsValves and flangesBurn protection
Installation guidance defines primer, aerogel mid-coat, topcoat, dew-point control and curing windows.
View technical profileCW-FTHLAerogel Fireproof Coating for Steel Structures
Waterborne ultra-thin intumescent coating that forms an expanded char layer under fire while aerogel slows heat transfer to steel.
- 66±3% solids
- 1.30 g/cm3 density
- 2 h surface dry
- 28-day full cure
Steel factoriesPetrochemical framesPower facilitiesCommercial steel
Designed for GB14907-2018 fireproof coating requirements. Fire-resistance ratings must be matched to project test reports.
View technical profileIndoor / Outdoor SystemsNon-Intumescent Fire Protection Coating
Thick-film fire protection coating systems for steel structures requiring higher dry film thickness and defined fire-resistance duration.
- 24 mm / 2.5 h reference system
- 100% solids
- 4 h surface dry
- 28-day full cure
Steel fire protectionOutdoor exposureIndustrial structures
Indoor dry density ≤500 kg/m3. Outdoor dry density ≤650 kg/m3.
View technical profileCW-WP-01Silicon-Based Penetrating Water Repellent
Low-viscosity penetrating water repellent that forms nanoscale hydrophobic interfaces inside porous concrete, masonry and stone substrates.
- 0.93 g/cm3 density
- pH 4-7
- 8-14% solids
- 250 ml/m2 recommended dosage
Concrete structuresStone protectionMortar and gypsumRepair and retrofit
2024W06363 report: 19% water absorption ratio, 0 mm permeability and no staining under multiple aging conditions.
View technical profileCW-AJAerogel Paste and Sealant Compound
Flexible aerogel composite paste for thin-layer encapsulation, sealing, wear resistance and local thermal insulation.
- 0.041 W/(m·K) thermal conductivity
- >1 MPa adhesion
- Class B combustion behavior
- Trowel or roller applied
Aerogel felt surface treatmentSubstrate coatingEncapsulationVibration and heat isolation
90C drying for 24 hours is recommended when higher adhesion is required.
View technical profile