Menu

Explore Products

All productsCompare material families and gradesAerogel Powders & GranulesFor coatings, composites and formulation developmentAerogel Blankets, Felts & MatsFor constrained space, hot/cold service and battery thermal controlAerogel Slurries, Coatings & PasteFor walls, roofs, pipes, valves and formulation workFireproof & Waterproof SolutionsFor steel fire-protection evaluation and porous mineral substrates

Explore Applications

All applicationsExplore projects by use caseBuilding Energy RetrofitLimited available thickness · Thermal bridgesIndustrial Pipe & Equipment InsulationComplex geometry · Inspection accessEV & ESS Thermal BarriersLimited pack space · Heat propagation controlLNG & Cryogenic InsulationLow-temperature service · Condensation controlSteel Fire ProtectionTarget fire resistance period · Steel section factorConcrete & Masonry WaterproofingSubstrate porosity · Water absorption

Resources

Technical Data SheetsRequest product-specific TDSSafety Data SheetsRequest applicable SDSTest DataReview data in contextInstallation GuidesCoating system guidanceProduct Selection GuideChoose by conditionsFAQCommon buyer questionsTechnical resourcesReviewed documentation and application guidance

Company

About Cowin MaterialsOur material focus and technical support approachContactDiscuss product selection or project conditionsNewsSource-linked industry briefs for technical buyersBlogTechnical articles and material-selection guidanceLocationsOffice location and contact detailsQualityProduct documentation and evaluation support Search the site

Aerogel Insulation Solutions for Building Energy Retrofit

Aerogel-based coatings and insulation materials can be evaluated for walls, roofs, thermal bridges and space-limited retrofit areas. Product selection depends on the existing substrate, climate conditions, moisture exposure, target thermal performance and local building requirements.

Simplified mineral wall section with separate coating layers
Illustration: primer, aerogel insulation and finish on a substrate. Not to scale.

Project challenge

Retrofit work often has limited available thickness, uncertain existing substrates and a need to coordinate thermal and moisture performance without disrupting the envelope.

Information to collect

  • Building area
  • Existing substrate
  • Climate exposure
  • Target thermal performance
  • Moisture or waterproofing concerns

Applicable technical data

Building Energy Retrofit data and scope
PropertyReported valueBasis
Thermal conductivity0.040 W/(m·K)Report XT226-250016; submitted sample under listed methods.
Added thermal resistance0.26 m²·K/WReport XT226-250016; submitted sample and report conditions.
VOC content35 g/LReport XT226-250016; submitted sample.

Verification steps

  1. Survey the substrate, moisture condition, thermal bridges and permitted thickness.
  2. Prepare a representative trial area with the selected primer, coating build and finish.
  3. Review the applicable TDS, test method and local requirements before specification.

System limits

  • A coating result is not a whole-building thermal calculation.
  • Facade, vapor and weather-exposure design must meet local requirements.

Documentation and project review

Match the document set to the selected grade, substrate, test method and complete system build.

Request applicable documentation

Last reviewed: 09 August 2026.

Application FAQ

Can a thin coating solve every retrofit requirement?

No. It must be evaluated against the target U-value, wall build-up, climate and applicable construction requirements.

Review your operating conditions

Send project details
WhatsApp