Material profile for project evaluation

Thermal conductivity0.040 W/(m·K)
Added thermal resistance0.26 m²·K/W
On this page

Overview

This waterborne aerogel insulation coating is intended for thin-build building-envelope and retrofit evaluations where board insulation is difficult to install.

The published evidence is for the identified test sample and system context. Surface preparation, primer, dry-film build and finish layer must be defined for each project.

Applications

Exterior wallsRoof retrofitFactory buildingsEnergy-saving renovation

Last reviewed

09 August 2026

Information is presented for technical evaluation, not as a project guarantee.

Technical evidence

Key specifications

Third-party report XT226-250016 recorded testing from 30 December 2024 to 19 February 2025. Data apply to the submitted sample and stated methods, not every substrate, film build or project configuration.

Thermal conductivity0.040 W/(m·K)

Report XT226-250016; tested sample; GB/T 25261-2018 and DG/TJ 08-2200-2024 listed.

Added thermal resistance0.26 m²·K/W

Report XT226-250016; tested sample and report conditions.

VOC content35 g/L

Report XT226-250016; tested sample.

Dry density / pull-off adhesion179 kg/m³ / 0.63 MPa

Report XT226-250016; tested sample.

Handling / storage

  • Confirm a clean, dry, stable substrate and compatible primer before trial application.
  • Build the insulation layer and protective finish to the approved system sequence and allow each layer to dry as specified.

Selection limits

  • Not a substitute for a whole-building energy model, facade design or local code review.
  • Thermal and adhesion results do not establish weathering, crack bridging or moisture performance for an untested substrate.

Source documents

  • Report XT226-250016: building insulation coating test record.
  • Supplied building aerogel insulation coating application workbook.
Request applicable documentation

Related applications

Product FAQ

Is 0.040 W/(m·K) a project guarantee?

No. It is a reported value for the submitted sample under the report conditions; verify the full system for the intended project.

Can this replace conventional facade insulation everywhere?

Selection depends on target thermal performance, permitted thickness, substrate, climate exposure and local building requirements.

Technical review

Need a match for your substrate, temperature or test standard?

Request a quote