CW-AC-01 / CW-AC-02Building insulation coating
Building Aerogel Thermal Insulation Coating
Waterborne thin-layer aerogel insulation coating used with primer and topcoat for exterior walls, roofs, retrofits and industrial buildings.

- Thermal conductivitySubmitted sample
- 0.040 W/(m·K)
- Added thermal resistanceSubmitted sample
- 0.26 m²·K/W
- VOC contentSubmitted sample
- 35 g/L
Overview
This waterborne aerogel insulation coating is intended for thin-build building-envelope and retrofit evaluations where board insulation is difficult to install.
The published evidence is for the identified test sample and system context. Surface preparation, primer, dry-film build and finish layer must be defined for each project.
- Primer
- Confirm a compatible primer for the prepared substrate.
- Aerogel insulation layer
- Define the build and drying intervals for the selected coating.
- Protective finish
- Select the finish for the intended exposure and curing conditions.
Typical applications: Exterior walls, Roof retrofit, Factory buildings, Energy-saving renovation.
Specifications and test basis
Submitted sample | report XT226-250016
| Property | Value | Basis |
|---|---|---|
| Thermal conductivity | 0.040 W/(m·K) | Report XT226-250016; tested sample; GB/T 25261-2018 and DG/TJ 08-2200-2024 listed. |
| Added thermal resistance | 0.26 m²·K/W | Report XT226-250016; tested sample and report conditions. |
| VOC content | 35 g/L | Report XT226-250016; tested sample. |
| Dry density / pull-off adhesion | 179 kg/m³ / 0.63 MPa | Report XT226-250016; tested sample. |
Third-party report XT226-250016 recorded testing from 30 December 2024 to 19 February 2025. Data apply to the submitted sample and stated methods, not every substrate, film build or project configuration.
Handling and selection limits
Handling / storage
- Confirm a clean, dry, stable substrate and compatible primer before trial application.
- Build the insulation layer and protective finish to the approved system sequence and allow each layer to dry as specified.
Selection limits
- Not a substitute for a whole-building energy model, facade design or local code review.
- Thermal and adhesion results do not establish weathering, crack bridging or moisture performance for an untested substrate.
Source documents
| Document | Applicable grade | Availability |
|---|---|---|
| Report XT226-250016: building insulation coating test record. | CW-AC-01 / CW-AC-02 | Request documentation |
| Supplied building aerogel insulation coating application workbook. | CW-AC-01 / CW-AC-02 | Request documentation |
Last reviewed: 09 August 2026.
Product FAQ
Is 0.040 W/(m·K) a project guarantee?
No. It is a reported value for the submitted sample under the report conditions; verify the full system for the intended project.
Can this replace conventional facade insulation everywhere?
Selection depends on target thermal performance, permitted thickness, substrate, climate exposure and local building requirements.
Discuss your application